PRODUCT INFORMATION
Product performance complies with the fast-setting index requirements of JC/T 2381-2016 in "Repair mortar".
|
NO. |
Performance Indicator |
Data |
|
1 |
Initial setting time, min |
≤ 30 |
|
2 |
Final setting time |
≤ 50 |
|
3 |
6h compressive strength, MPa |
≥ 15.0 |
|
4 |
24h compressive strength, MPa |
≥ 20.0 |
|
5 |
1d (untreated) tensile bonding strength, MPa |
≥ 0.6 |
|
6 |
28d flexural strength, MPa |
≥ 6.0 |
|
7 |
28d compressive strength, MPa |
≥ 30.0 |
|
8 |
28d compression ratio |
≤ 7.0 |
|
9 |
14d (untreated) tensile bonding strength, MPa |
≥ 1.0 |
|
10 |
14d (immersion) tensile bonding strength, MPa |
≥ 0.9 |
|
11 |
14d (thermal aging) tensile bonding strength, MPa |
≥ 0.7 |
|
12 |
14d (25 freeze-thaw cycles) tensile bonding strength, MPa |
≥ 0.7 |
|
13 |
28d shrinkage rate, % |
≤ 0.10 |
|
14 |
Interface bending tensile strength, MPa |
≥ 2.0 |
|
15 |
Chloride ion content, % |
≤ 0.06 |
APPLICATION PROCEDURE
· Clean the surface of the foundation, ensuring no debris such as gravel or dust. Before grouting, the foundation surface should be kept moist, without standing water.
· Wait until there is no standing water, start brushing the interface agent to ensure that the interface agent is uniform.
· On-site, determine the water-cement ratio based on the recommended ratio. Water temperature between 5-30°C is suitable, and mechanical or manual mixing can be used. Mechanical mixing should be done for 1-2 minutes. For manual mixing, first add 2/3 of the water and mix for 3 minutes, then add the remaining water and continue mixing until uniform.
· Construction should be carried out with caution under harsh environmental conditions such as direct sunlight and strong winds. After construction, immediately cover with plastic film and add grass curtains or blankets for moisture retention and curing.
TECNICAL INFOMATION
|
Product Technical Parameters |
Packing Specification |
25kg/bag |
|
Character |
Grey mortar |
|
|
Executive Standard |
JC/T2381-2016 |
|
|
Mixing ratio |
Powder: Water = 1:0.15 |
|
|
Shelf life |
6 months when stored unopened in a cool, dry place. |
|
|
Construction Technical Parameters |
Construction Consumption |
2-3t/m³ |
|
Construction Environment |
Outdoor construction should be avoided in high temperature, frost, direct sunlight, or windy rainy weather. When the temperature is below 5°C, insulation measures should be done. |
|
|
Operable Time |
30min |
FEATURES AND BENEFITS
· Good property for self-flow: No need for vibration, easy to apply.
· High stability: No defects such as shrinkage cracks after molding.
· High adhesion: no breakage, no cracking.
· Strong durability: It belongs to inorganic bonding materials and has a service life greater than that of the foundation concrete. After hundreds of fatigue tests, there was no significant change in strength after 50 freeze-thaw cycles.
· Repair of cracks, honeycombs, voids, hanging blocks, and exposed reinforcement on concrete and cement floors.
· Repair of damages to road surfaces such as high and low speeds, toll stations, service areas, gas stations, and airports.
Good property for self-flow
High stability, High adhesion
Strong durability