|
Item |
Description | |
| Single-Side Self-Adhesive | Double-Side Self-Adhesive | |
|
Width (m) |
1 | 1 |
|
Thickness (mm) |
1.5、 2.0 |
1.5、 2.0 |
|
Length (m) |
20 |
20 |
|
Roll Size (m2/roll) |
20 | 20 |
|
Upper Surface Material |
HDPE cross-laminated film |
Release film |
|
Lower surface Material |
Release film |
Release film |
| Description | Test Methods | Values |
|---|---|---|
|
Tensile Strength(MD/CD)[N/mm2] |
ASTM D412 | ≥4/≥4 |
|
Elongation at break (MD/CD)[%] |
ASTM D412 | ≥300/≥300 |
|
Low temperature flexibility (-10℃) |
ASTM D5147 | No crack |
|
Puncture Resistance[N] |
ASTM E154 | ≥180 |
|
Water Vapour Transmission, g/(m2·24h) |
ASTM E96/E96M-22 |
<0.3 |
|
Tear Strength (MD/CD)[N/mm] |
ASTM D624 | ≥25/≥25 |
|
Peel adhesive to concrete[N/mm] |
ASTMD903-98 (2017) | ≥1.5 |
|
Hydrostatic Pressure Resistance (100 psi) |
ASTM D5385 | No leakage |
|
Static Crack Bridging @ 3.2mm |
ASTMC1305/C1305M-16 | No crack |
|
Watertightness (7bar,24h) BS |
EN1928 Method: B | No leakage |
Application Instructions
Surface Preparation: Surfaces should be structurally sound and free of voids, loose aggregate and sharp protrusions. Remove contaminants such as grease, oil and wax from exposed surfaces.
Priming: Before application, substrate should be sprayed or rolled with solvent/water-based primer fully.
Membrane Application: Application on the Horizontal Surfaces: Place the membrane to application area. Roll out or kick out the membrane to release the stress. Apply membrane from the low point to the high point so that laps shed water. Adjacent rolls are aligned and overlapped a minimum of 80mm at the side and ends with a roller or firm hand pressure to ensure complete adhesion and continuity between the layers. Stagger all the end laps. Roll the whole membrane firmly and completely to eliminate air pocket.
Vertical Surfaces: Terminate the membrane at grade level. Press the membrane firmly to the wall. Failure to use heavy pressure at terminations can result in a poor seal. A termination bar may be used to ensure a tight seal.
Protection: Keep the membrane clean and free outside damage.
Backfill: Place backfill as soon as possible. Take care during backfill operation to avoid damage to the waterproofing system. Backfill should be added and compacted in 300 mm to 500 mm lifts. A protection of the membrane should be considered.
Features & Benefits
· Safe, easy and fast installation.
· No need for special equipment and flame.
· Excellent initial and long term adhesion.
· Direct application on wet substrate.
· For single-side self-adhesive membrane: Excellent mechanical resistant, such as high tensile strength, good puncture and tear, and high nail shank tear strength, good dimensional stability.
· Resistant to chemical corrosion: Resistant to most soil conditions, the membrane is designed to provide effective protection against soils and groundwater.
Superior mechanical resistance and stability
Effective protection against chemical corrosion
Safe, easy and fast installation
No need for special equipment and flame
Excellent initial and long term adhesion
Direct application on wet substrate