Items |
GardMem-2000 |
|||
|
Dimensions |
5-meter |
10-meter |
20-meter |
30-meter |
|
Thickness/mm |
0.50 |
0.50 |
0.50 |
0.50 |
|
Width/m |
1.0 |
1.0 |
1.0 |
1.0 |
|
Roll Weight/kg |
0.80-0.85 |
1.60-1.70 |
3.20-3.40 |
4.80-5.10 |
Custom lengths are often available. The above are typical data for the testing sample rolls.
Physical performance
Code compliance:ANSI A118.10, American National Standard Specification for Load Bearing, Bonded, Waterproof Membrane for Thin-Set Ceramic Tile and Dimension Stone Installation.
|
Entry |
Properties |
Test method |
Specification |
GardMem-2000 |
|
1 |
Seam strength, lb/2in |
ASTM D751, ANSI A118.10 |
≥ 16 |
100 |
|
2 |
Breaking strength, psi |
ASTM D751, ANSI A118.10 |
≥ 170 |
2185 (MD) 2072 (CD) |
|
3 |
Dimensional stability (-15℉) |
ASTM D1204, ANSI A118.10 |
≤ 0.7% |
-0.029% (L) 0.027% (W) |
|
Dimensional stability (+158℉) |
0.016% (L) 0.068% (W) |
|||
|
4 |
Waterproofness |
ASTM D4068-01, Annex2; ANSI A118.10 |
No leak |
Pass |
|
5 |
Shear strength to ceramic tile (7 day), psi |
ASTM C482-9.8, ANSI A118.10 |
≥ 50 |
158 |
|
6 |
7-day water immersion shear strength, psi |
110 |
||
|
7 |
4-Week dry, psi |
147 |
||
|
7 |
Fungus and microorganism resistance |
ANSI A118.10 |
No fungus and organism grown |
Pass |
|
8 |
Water transmission rate (perm) |
ASTM E96 (Water method) |
\ |
0.05 |
|
9 |
Crack-bridging ability |
ASTM C836 |
\ |
1mm |
Installation Instructions
Surface preparation:
Ensure the substrate is clean, even, loading bearing and free from debris. The surface should be level and smooth to ensure proper adhesion.
Apply thin-set mortar and membrane:
The GardMem membrane is adhered to the substrate with thin-set mortar. Apply the thin-set mortar to the substrate with a 1/4" x 3/16" (6×5mm) V-notched trowel, then press the membrane onto the mortar with the flat side of trowel to eliminate air pockets.
Seaming & overlaps:
Seams should be constructed by overlapping the edges of at least 2" (5 cm) using ANSI A118.4 compliant thin-set mortar, or by abutting the edges and covering the joints with GardMem-BAND.
For inside and outside corners, adhere preformed corner sections (GardMem-IC, GardMem-OC).
For wall and floor connections, use GardMem-BAND.
Install GardMem-PS pipe seals at showerhead, body spray, and GardMem-VS at the mixing valve.
GardMem membrane should be separated at existing expansion, structural and flexible edge joints. Cover the joints with GardMem-FlexBAND. To allow for greater movement, the center section of the GardMem-FlexBAND can be tucked into the cavity of the expansion joints.
Flood testing of the waterproofing system: Prior to setting tile, wait for 24 hours to allow for final set of the mortar before testing to ensure waterproofing performance of the whole system.
Tile Installation: Once the membrane is installed, tiles can be applied directly to the exposed membrane surface with thin-set mortar.
Storage
Follow a two-year shelf life and use it on a first-in, first-out basis.
Store in a well-ventilated, dry area, away from sunlight and rain. The storage temperature should not exceed 120℉.
Keep off the ground under tarps or other protective coverings to prevent exposure to rain and ground moisture.
Avoid prolonged exposure to direct sunlight.
GardMem-2000 sheet is used as waterproofing, uncoupling and anti-fracture membrane for cracked and damp substrates and substrates that are not fully cured before installing ceramic and stone tiles for internal and external surfaces. GardMem system is suitable for waterproofing various wet room, such as shower room, bath-tub surroundings, kitchens, balconies and terraces. It can create an uncoupling and vapor barrier layer on damp substrate.
Waterproofing & Vapor-Proof
Prevents Mold Growth
Flexible
Thin Profile
Bonding Surface
Quick & Easy Installation
Durability
Seamless System Integration
Unique fleece design
Superior Vapor Management